Modes
Check out our video on how to adjust the visible range for the O3R cameras:
Overview
The mode parameter selects a standard measurement range or a cyclic sequence of ranges.
The default is standard_range6m.
Mode |
Measurement range |
|---|---|
|
2 m |
|
3 m |
|
4 m |
|
5 m |
|
6 m |
|
Alternating 4 m and 2 m |
|
Alternating 6 m and 3 m |
See the acquisition parameter references for mode-specific settings.
Description
The O3R has the specificity to provide several measurement ranges. A distance measurement is computed only for a subspace of the scene. Elements fully outside of the range are not taken into account and have no impact on the measurement (for instance by causing artifacts like stray-light or Multi-Path Interference).
Note: Objects very close to the beginning or end of the measurement range can still have an impact on the measurement.
The O3R provides five standard measurement ranges: two, three, four, five, and six meters. These ranges use different frequencies to perform the Time-of-Flight (ToF) measurement and therefore show different characteristics, especially in how they are affected by artifacts. The longer-range modes show higher noise levels than the shorter-range modes.
Cyclic modes
Cyclic modes alternate between two measurement ranges from frame to frame:
cyclic_4m_2m_4m_2malternates between the four-meter and two-meter ranges.cyclic_6m_3m_6m_3malternates between the six-meter and three-meter ranges.
Example
Let’s look at a simple scene: three boxes are placed in front of the camera, one, two, and three meters away (see image below).

The table below shows the computed distance measurement in the distance image view and the point cloud view for two of the available modes (2 m and 4 m):
Mode |
Distance Image |
Point Cloud |
|---|---|---|
2 m |
|
|
4 m |
|
|
The third box, which is three meters away from the camera, is outside of the measurement range when using the two-meter mode; however it is visible when using the four-meter mode.
Note: Using the offset parameter in combination with the mode is interesting and allows for a lot of flexibility in using the coded modulation ToF technology. We encourage you to investigate strategies using multiple modes in combination with offsets.