Modes

Check out our video on how to adjust the visible range for the O3R cameras:

Overview

The mode parameter selects a standard measurement range or a cyclic sequence of ranges. The default is standard_range6m.

Mode

Measurement range

standard_range2m

2 m

standard_range3m

3 m

standard_range4m

4 m

standard_range5m

5 m

standard_range6m

6 m

cyclic_4m_2m_4m_2m

Alternating 4 m and 2 m

cyclic_6m_3m_6m_3m

Alternating 6 m and 3 m

See the acquisition parameter references for mode-specific settings.

Description

The O3R has the specificity to provide several measurement ranges. A distance measurement is computed only for a subspace of the scene. Elements fully outside of the range are not taken into account and have no impact on the measurement (for instance by causing artifacts like stray-light or Multi-Path Interference).

Note: Objects very close to the beginning or end of the measurement range can still have an impact on the measurement.

The O3R provides five standard measurement ranges: two, three, four, five, and six meters. These ranges use different frequencies to perform the Time-of-Flight (ToF) measurement and therefore show different characteristics, especially in how they are affected by artifacts. The longer-range modes show higher noise levels than the shorter-range modes.

Cyclic modes

Cyclic modes alternate between two measurement ranges from frame to frame:

  • cyclic_4m_2m_4m_2m alternates between the four-meter and two-meter ranges.

  • cyclic_6m_3m_6m_3m alternates between the six-meter and three-meter ranges.

Example

Let’s look at a simple scene: three boxes are placed in front of the camera, one, two, and three meters away (see image below). RGB view of the scene

The table below shows the computed distance measurement in the distance image view and the point cloud view for two of the available modes (2 m and 4 m):

Mode

Distance Image

Point Cloud

2 m

Distance image for the two meter mode

Point cloud for the two meter mode

4 m

Distance image for the four meter mode

Point cloud for the four meter mode

The third box, which is three meters away from the camera, is outside of the measurement range when using the two-meter mode; however it is visible when using the four-meter mode.

Note: Using the offset parameter in combination with the mode is interesting and allows for a lot of flexibility in using the coded modulation ToF technology. We encourage you to investigate strategies using multiple modes in combination with offsets.