Time synchronization
To compare camera or ODS timestamps with vehicle logs, synchronize the OVP93x VPU and the vehicle to the same time reference. Have your NTP server running and reachable before the VPU starts to avoid a clock jump during acquisition.
Configure the VPU
No NTP server is configured by default. Use either ifmVisionAssistant or the ifm3d Python API to configure the VPU’s SNTP client.
Using ifmVisionAssistant
Open VPU settings and select General.
Enable (S)NTP server.
Select + and enter your NTP server address.
Using Python
Replace 192.168.0.110 with your NTP server address:
from ifm3dpy.device import O3R
vpu = O3R()
vpu.set({"device": {"clock": {"sntp": {
"availableServers": ["192.168.0.110"],
"active": True,
}}}})
Verify synchronization
Read the VPU’s SNTP status:
ifm3d ovp9xx config get --path /device/clock/sntp
systemClockSynchronized must be true before you compare timestamps across devices.
activeServerAddress identifies the server the VPU is using.
If systemClockSynchronized remains false, check that active is true, that availableServers lists the intended server, and that the VPU can reach it.
For acquisition and receive times, see Frame timestamps.