# Modes Check out our video on how to adjust the visible range for the O3R cameras: :::{youtube} LhtemnOsJp4 ::: ## Overview The `mode` parameter selects a standard measurement range or a cyclic sequence of ranges. The default is `standard_range6m`. | Mode | Measurement range | | --- | --- | | `standard_range2m` | 2 m | | `standard_range3m` | 3 m | | `standard_range4m` | 4 m | | `standard_range5m` | 5 m | | `standard_range6m` | 6 m | | `cyclic_4m_2m_4m_2m` | Alternating 4 m and 2 m | | `cyclic_6m_3m_6m_3m` | Alternating 6 m and 3 m | See the [acquisition parameter references](AcquisitionParams/index_acquisition_params.md) for mode-specific settings. ## Description The O3R has the specificity to provide several measurement ranges. A distance measurement is computed only for a subspace of the scene. Elements *fully* outside of the range are not taken into account and have no impact on the measurement (for instance by causing artifacts like [stray-light](./ProcessingParams/strayLight.md) or Multi-Path Interference). >Note: Objects *very* close to the beginning or end of the measurement range can still have an impact on the measurement. The O3R provides five standard measurement ranges: two, three, four, five, and six meters. These ranges use different frequencies to perform the Time-of-Flight (ToF) measurement and therefore show different characteristics, especially in how they are affected by artifacts. The longer-range modes show higher noise levels than the shorter-range modes. ### Cyclic modes Cyclic modes alternate between two measurement ranges from frame to frame: - `cyclic_4m_2m_4m_2m` alternates between the four-meter and two-meter ranges. - `cyclic_6m_3m_6m_3m` alternates between the six-meter and three-meter ranges. ## Example Let’s look at a simple scene: three boxes are placed in front of the camera, one, two, and three meters away (see image below). ![RGB view of the scene](resources/modes_scene.png) The table below shows the computed distance measurement in the distance image view and the point cloud view for two of the available modes (2 m and 4 m): | Mode| Distance Image| Point Cloud| |--|--|--| | 2 m| ![Distance image for the two meter mode](resources/2m_mode_distance.png)| ![Point cloud for the two meter mode](resources/2m_mode_cloud.png)| | 4 m| ![Distance image for the four meter mode](resources/4m_mode_distance.png)| ![Point cloud for the four meter mode](resources/4m_mode_cloud.png)| The third box, which is three meters away from the camera, is outside of the measurement range when using the two-meter mode; however it is visible when using the four-meter mode. > Note: Using the [offset](./AcquisitionParams/index_acquisition_params.md#offset) parameter in combination with the mode is interesting and allows for a lot of flexibility in using the coded modulation ToF technology. We encourage you to investigate strategies using multiple modes in combination with offsets.