Stress Tests

The stress testing results in assessing the performance, reliability and stability of the O3R system. These tests will be performed by subjecting the hardware components to extreme stress conditions(internal and external) under different conditions.

The external stress factors include:

  • Vibration

  • Shock

  • EMV

  • Temperature

The internal stress (as induced by the O3R system itself) includes:

  • VPU stressing: CPU, GPU, RAM

  • Head stressing: maximum load, that is maximum framerate and acquisition times for all camera heads

To monitor the system’s operational state, ifm suggests monitoring the following O3R system data steams and diagnosis outputs:

  • Diagnosis information

  • O3R internal temperatures

  • (O3R data availability)

Specifications

The technical specification is available from the ifm.com under respective product’s page. The following table is used for demonstration purposes only.

Test type

Norm

description

EMC

EN IEC 61000-6-4

radiation of interference / residential, commercial and light-industrial environments

EN IEC 61000-6-2

noise immunity / industrial environments

Shock resistance

DIN EN 60068-2-27

50 g / (11 ms) not repetitive

DIN EN 60068-2-27

40 g / (6 ms) repetitive

Vibration resistance

DIN EN 60068-2-6

2 g / (10…150 Hz)

DIN EN 60068-2-64

2.3 g RMS / (10…500 Hz)

Electrical safety

DIN EN 61010-2-201

electrical supply only via PELV circuits

Test type

Range

description

Temperature

[°C] -10…40

O3R335 ambient operating temperature

1. Vibration and Shock

These tests are independent of the system’s live operation, that is can be performed in an offline state - without monitoring the live status.

The O3R systems functionality can be verified explicitly by comparing sets of functionality before and after the test runs. These sets of functionality can include:

  • complete boot-up of the system

  • availability of all connected cameras (heads) and a review of their data streams

Alternatively, the functionality can be verified implicitly by testing a complete system behavior (for example your AGV / AMR) before and after the test. The benchmarking results should stay the same within the boundary of the benchmark’s repeatability.

2. EMV Testing

These tests typically involve testing for EMV emission, EMV emission, and self-interference immunity. Depending on the norm not all parts may apply and different thresholds may be required.

During testing the operation of the device may be interrupted for short amounts of time, according to the norm, and live operation has to be resumed within its time tolerance. Please test the O3R system in its intended mounting place including all surrounding components.

The system’s operational state can be determined by the time difference between consecutive timestamps: for example O3R VPU CPU clock-based timestamps or an independent test machines clock.

The (CPU-based) data frame timestamp is generated by the IPC (VPU) clock when new data is acquired from a camera head. For test purposes, the timestamp latency and jitter should be sufficiently low (latency and jitter).

This may either be done on a recorded dataset in the post or on data retrieved in live operation.

Note

**Please compare these statistical values against typical values under undisturbed operation conditions, to ensure the system's capability to retrieve the required data at full framerate!**

3. Temperature Testing

A first set of temperature tests is typically run during a proof of concept phase on a component level, that is the O3R system and its intended (prototype) mounting setup are tested in a smaller temperature chamber. This is a good indication of whether the passive cooling capabilities of the camera and VPU mounting are sufficient for the full ambient temperature range. Please set all 3D camera heads to their maximum allowed framerate: 20 Hz. Additionally you can change the exposureShort from 400 to 1000.

Load on the VPUs CPU and GPU can be introduced by running a functional ODS application instance, or by artificially introducing CPU and GPU load via tools such as stress and gpu-burn.

In a secondary step temperature tests are repeated on a fully assembled machine level, for example the complete AGV / AMR is tested in larger temperature chambers, with all active components in live operation. This may include:

  • The battery management system (BMS) is under full load.

  • Active cooling of the battery cells if applicable.

  • Additional heat introducing “computers,” for example: IPCs, PLCs, …

  • Active cooling, that is fans that distribute energy over larger passive heat sinks or perform an exchange of air from the inside to the outside of the machine

  • …

Additionally “heat” is introduced via the temperature chamber to mimic maximum ambient heat levels during operation. This test will determine the operability of the O3R system, based on the effectiveness of the whole cooling concept.

Operate each component within its specified ambient temperature range. For O3R335, this range is −10 to +40 °C. Internal temperature readings do not replace the ambient operating limits.

Temperature monitoring

Use temperature readings and diagnostic messages to monitor thermal conditions.

Temperature protection

For O3R335, temperature protection stops and restarts camera head illumination under the following conditions. These internal head-temperature thresholds are not ambient operating limits or VPU shutdown thresholds.

Condition

Head temperature

Precondition

System reaction

Overtemperature

> +81 °C

Normal operation

Report a diagnostic error and stop head illumination.

Recovery from overtemperature

≤ +72 °C

Overtemperature error state

Reset the error and restart head illumination.

Undertemperature

≤ −14 °C

Normal operation

Report a diagnostic error and stop head illumination.

Recovery from undertemperature

> −13 °C

Undertemperature error state

Reset the error and restart head illumination.

Temperature readings and diagnostics

Read the reported temperatures using the SDK example or CLI below. Use diagnostic messages to identify temperature-protection events.