Software and Controls Integration Guide

This guide is for software and controls engineers integrating the O3R into a vehicle or work-cell. It provides an overview of the integration process and links to detailed documentation on specific topics.

API interface

The O3R is accessed via the ifm3d API v2.x (Python or C++). This is the primary interface for configuration, data streaming, and application control.

PLC interface

Industrial controls environments can integrate the O3R applications directly over a PLC interface. See the PLC documentation for the setup guide, function blocks, and the TCP/IP and EtherNet/IP interfaces.

Available applications

Application

Purpose

ODS (Obstacle Detection System)

Real-time 3D obstacle detection, occupancy grid and zone outputs

See the ODS documentation for details.

ODS software-integration checklist

The key software integration tasks are:

  1. Connect to the O3R via the ifm3d API and verify data streaming.

  2. Configure ODS parameters (active ports, zones, presets).

  3. Implement diagnostics handling — the vehicle must stop if the ODS group severity is critical, major, or not available.

  4. Wire zone state outputs to vehicle speed commands or emergency stop signals.

  5. Validate end-to-end latency against vehicle stopping distance requirements.

See the ODS getting started guide for detailed steps, and the diagnostics documentation for status monitoring.

Support

Contact the ifm support team at the outset of any project for architecture guidance and integration planning: support.efector.object-ident@ifm.com