Getting started with ODS
Check out this video to get started with ODS:
Alternatively, you can read through the steps below.
Prerequisites
An OVP931 device (this comes with the required ODS app pre-installed),
One or more O3R335 cameras,
An Ethernet cable, FAKRA cable and power supply as specified in the wiring instructions,
The ifm Vision Assistant, which is the standard GUI from ifm used to interface with all 3D cameras (download the latest version on ifm.com).
Step 0: Setup
Before wiring and calibrating the cameras, review the ODS mounting recommendations and the O3R335 clearance definition and illustrations.
First, make sure to properly wire the O3R perception platform. You can follow the wiring instructions.
Once the OVP93x and cameras are wired, open up the ifm Vision Assistant and make sure you can connect to the O3R platform and are able to receive data.
Step 1: Extrinsic calibration
Quick start: enter an approximate camera pose
For a first look at the ODS occupancy grid, enter the approximate mounting position and orientation of each 3D camera in vehicle coordinates. Do not use this estimate to evaluate detection performance.
In ifmVisionAssistant, open manual calibration under Port settings and select the camera port.
Select the orientation that matches the mounted camera and enter its offsets from the vehicle coordinate origin. The example shows a level, forward-facing camera 50 cm above the floor. If the vehicle origin is at floor level, the vertical offset in this example is 0.50 m. Use the offsets for your installation.
Before performance testing or deployment
Calibrate each ODS camera in its final mounting position using one of the two calibration routines:
Use static camera calibration (SCC) with the vehicle and checkerboard stationary.
Use the motion camera calibration (MCC) wizard to calibrate during straight-line vehicle motion.
Use CAD values instead of SCC or MCC only if you have verified the actual camera position and orientation against the model and the mounting deviations are small enough for your application’s accuracy requirements.
For operation on a moving vehicle, calibrate the VPU as a separate step. Use the same vehicle coordinate system as for the cameras so ODS can interpret motion measured by the VPU’s IMU.
Step 2: Create an ODS application
In the “Application” tab, create an ODS application instance.
An application instance is created with default settings. By default, all connected 3D ports are added to the list of ports for the ODS app to use.
Note
When first instantiating the application, diagnostic messages may appear at the bottom of the screen. The ODS application performs some checks related to the motion of the vehicle, which may take some time to succeed while the application is running. Typically, these will disappear after the ODS has been able to initialize properly.
Note
When using multiple applications on a single device, keep in mind that the maximum number of simultaneous application instances is 20. The maximum number of application of each type that can be configured is:
1 ODS application
1 PLC application
8 MCC applications
8 SCC applications
Multiple applications using the same camera cannot be active at the same time. Switch all the applications to CONF except the one currently running.
Step 3: Start ODS
To start ODS, you can simply set the state parameter to "RUN":
Once the application is running, objects identified as obstacles will appear in the occupancy grid.
You can also activate the default zones, by clicking on the “Set Example Zones” button:
Watch the video:

Note
If you notice that the point cloud appears to flicker in the visualization, you can use the frame filter. The frame filter does not change the parameters of any port and is used for visualization purposes only.